Model IRN100H-CC
Needs repair
Notes from compressor technician:
Arrived on site. Fused disconnect is off. Checked fuses, L2 fuse is open. Removed and tagged as bad.
Performed visual inspection of drive components. Noted that U phase snubber capacitor on out put module had
arc marks. Removed motor leads and tested with mega ohm meter at 1000 vdc. Motor is not grounded, but
insulation is failing. Performed input/ output diode tests on drive. Output U phase is shorted. Advised customer
of findings and will quote repairs.
Parts needed: IR REPLACEMENT OUTPUT MODULE #23036676